25. DISPLAYING AND SETTING DATA
B–63682EN/01
NC FUNCTION
192
On the above screen, the built–in port is selected.
In this example, pressing the [PCMCIA] soft key displays a switching
confirmation message. Pressing the [EXEC] soft key causes device
switching.
NOTE
Information about the selected device is stored in
nonvolatile memory.
Next time the power is turned on, therefore, the device
previously selected can be used still.
A target of setting is selected on the Ethernet parameter setting screen.
D Pressing the [BOARD] soft key enables Ethernet port parameters for
the option board to be set.
D Pressing the [BLT–IN] soft key enables Ethernet port parameters for
the built–in Ethernet port to be set.
D Pressing the [PCMCIA] soft key enables parameters for the PCMCIA
Ethernet card to be set.
NOTE
Keep in mind that the Ethernet parameters for the following
items are independent from one another.
D Ethernet port on the option board side
D Built–in Ethernet port for incorporation
D PCMCIA Ethernet card for incorporation
Ethernet parameter
setting