B-63343EN/02 USER PROGRAM 1.OUTLINE OF USER PROGRAM
- 7 -
BH8x_nn.LNK
The following is a sample link control file used to create a manual
guide control module.
/*
/* Conversation MACRO Sample program LINK control file.
/* ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
/*
/* executer file 'MANUAL GUIDE FOR DIVISION MODULE TYPE'
/*
CNC =BH8x_nn.EX1 /* nn=EDITION NO. Executor file name
CNC2 =BH8x_nn.EX2 Executor file name
CNC3 =BH8x_nn.EX3 Executor file name
PCODE=REAR Be sure to include it.
/*
/* compile parameter P9000 - P9009 and P9010 - P9059
/*
P9000=11000000 Set ROM size 3M.
P9001=10000001 Set #7 = 1, #0 (SEQN) = 1, #1 (LOC4) = 0.
P9002=11100000 Set #7(EXT1)=1, #6(PWSR)=1, #5(DAUX)=1.
P9003=10001001 Set #7(TCF)=1, #3(GPNT)=1, #0(ONMSK)=1.
P9006=00001000 Set #7(MFOPT)=0, #6(TFOPT)=1, #2(TTVR2)=0.
P9007=01000000 Set #7(MFOPT)=0, #6(TFOPT)=1, #2(TTVR2)=0.
P9009=00000100 Set #2(CM30)=1, #1(LM30)=0.
P9013=200
P9023=320
P9024=321
/*P9030=27
/*P9031=28
/*P9033=97
P9037=7 (Number of those P code variables #10000 to #19999 that are used) Be sure to set 7.
P9044=2044 (Number of those P code variables #10000 to #19999 that are used) Be sure to set 7.
P9038=1030 Trade mark display user program number
/*P9100=00000001 /* for debug
/*
/* Link file's
/*
FILE=BH8x_nn /* EXECUTION MACRO
/*
Manual guide execution macro file name