3/3
SHEETDESCRIPTIONDESIGN DATE EDIT
01 Mutai Newl
re
istered
TITLE: PROFIBUS-DP Board OPERATOR’S MANUAL
For FS 30i/300i, 31i/310i, 32i/320i–MODEL A
Note about the number of available I/O module Units
B-63994EN/02-1
FANUC LTD.
04.10.14
DRAW.NO.
Note
(1) If Slave parameter length exceeds 240 bytes, the following
message is displayed at the COMMUNICATION STATUS screen
of PROFIBUS setting screen on CNC.
PARAMETER ERR1 : 0003
PARAMETER ERR2 : 00XX
(“XX” is the smallest slave number where an error occurred.)
(2) According to the limitation of the above-mentioned, the number of
available I/O module units might be fewer than a capacity of its
slave unit defined at Slave unit’s manual, GSD file, etc.
(3) In an instance, approximate 40 I/O module units can be available
per a slave sataion. (It is a rough estimate. The length of USER
PRM DATA and CONFIG DATA is variable, depending upon kinds
of I/O module units, as well as the number of units.)
(4) By using CNC Setting Tool for PROFIBUS(A08B-9510-J530), this
check is executed automatically.