1.PROFIBUS-DP MASTER FUNCTIONS SETTING B-63994EN/02
- 30 -
OPERATION MODE screen
Procedure
1 Press soft key [MODE] to display the OPERATION MODE
screen.
OPERATION MODE screen
Display item
Item Description
CURRENT MODE The current operation mode is indicated.
Setting item
Item Description
INDICATION ADDRESS Set the start address of a mode indication
address. (The size is one byte.)
2 To select the STOP mode, CLEAR mode, or OPERATE mode
defined in the PROFIBUS specification, as operation mode, press
soft key [STOP], [CLEAR], or [OPERATE], respectively.
The setting order must be [OPERATE] → [CLEAR] → [STOP]
or [STOP] → [CLEAR] → [OPERATE].
3 To post the current operation mode to a PMC address, set
INDICATION ADDRESS.