B-63994EN/02 SETTING 2.PROFIBUS-DP SLAVE FUNCTIONS
- 53 -
; Slave specific parameters
;
Freeze_Mode_supp = 0
Sync_Mode_supp = 0
Auto_Baud_supp = 1
Set_Slave_Add_supp = 0
User_Prm_Data_Len = 0
Min_Slave_Intervall = 1
Modular_Station = 1
Max_Module = 1
Max_Input_Len = 244
Max_Output_Len = 244
Max_Data_Len = 244
;
Module = "32 Byte Out, 32 Byte In" 0xC0,0x1F,0x1F
EndModule
Module = "28 Byte Out, 28 Byte In" 0xC0,0x1B,0x1B
EndModule
Module = "24 Byte Out, 24 Byte In" 0xC0,0x17,0x17
EndModule
Module = "20 Byte Out, 20 Byte In" 0xC0,0x13,0x13
EndModule
Module = "16 Byte Out, 16 Byte In" 0xC0,0x0F,0x0F
EndModule
Module = "12 Byte Out, 12 Byte In" 0xC0,0x0B,0x0B
EndModule
Module = " 8 Byte Out, 8 Byte In" 0xC0,0x07,0x07
EndModule
Module = " 4 Byte Out, 4 Byte In" 0xC0,0x03,0x03
EndModule
Module = " 2 Byte Out, 2 Byte In" 0xC0,0x01,0x01
EndModule
Module = "32 Byte Out, 1 Byte In" 0xC0,0x1F,0x00
EndModule
Module = " 1 Byte Out, 32 Byte In" 0xC0,0x00,0x1F
EndModule
;
NOTE
A slave station manufactured by FANUC allows the DI size and DO size to be
freely changed as long as the total of DI/DO sizes is within 244 bytes. When
setting a DI size and DO size other than the above, see "Explanation of
configuration data" in Section 2.5, "SETTING SLAVE PARAMETERS TO USE A
SLAVE STATION MANUFACTURED BY FANUC".