1.PROFIBUS-DP MASTER FUNCTIONS SETTING B-63994EN/02
- 16 -
[ AUTO (ADDR) ] :
When pressing soft key [AUTO (ADDR)] after setting the
diagnostic data size of each slave DGN SIZ and entering the
number of stations, PMC addresses DGN ADDR for
diagnostic data of the valid slave station numbers of the
slave station on which the cursor is placed and later stations
are assigned contiguously by the number of entered stations.
When the slave station number or diagnostic data size is not
determined, assignment is stopped at that point.
[ DELETE] :
Pressing soft key [DELETE] after entering the number of
stations disables the slave station on which the cursor is
placed and later stations by the number of stations and
initializes them.
Display item
Item Description
IDX Index number
Index numbers for 48 stations are provided (see
NOTE below).
SLAVES Number of slave stations for which
communication is enabled.
Setting item
Item Description
Set a slave number.
For the slave stations for which communication
is enabled, "*" appears to the left of this
parameter. This parameter is set by soft keys
[ENABLE] and [DISABLE].
NO
Setting range : 0 to 125
Set the number of slots in which I/O modules
are placed.
For details on a slot, see "Slot" later.
NSL
Setting range : 1 to 128 (Note)
Set the start address of diagnostic data.
For details on diagnostic data, see "Diagnostic
data" later.
ADDR
Setting range : See CAUTION below.
Set the size of diagnostic data.
DGN
SIZ
Setting range : 0 to 242 (bytes)