2.PROFIBUS-DP SLAVE FUNCTIONS SETTING B-63994EN/02
- 56 -
(a) Formats for using both input and output
<1> Input size = 1 to 64, and output size = 1 to 64
Data length: 3
Data: C0 XX YY
<2> Input size = 65 to 128, and output size = 65 to 128
(However, DI SIZE + DO SIZE ≤ 244 must be satisfied.)
Data length: 6
Data: C0 3F 3F C0 XX YY
<3> Input size = 1 to 64, and output size = 65 to 128
Data length: 5
Data: C0 3F YY 80 XX
<4> Input size = 1 to 64, and output size = 129 to 192
(However, DI SIZE + DO SIZE ≤ 244 must be satisfied.)
Data length: 7
Data: C0 3F YY 80 3F 80 XX
<5> Input size = 1 to 64, and output size = 193 to 244
(However, DI SIZE + DO SIZE ≤ 244 must be satisfied.)
Data length: 9
Data: C0 3F YY 80 3F 80 3F 80 XX
<6> Input size = 65 to 128, and output size = 1 to 64
Data length: 5
Data: C0 XX 3F 40 YY
<7> Input size = 129 to 192, and output size = 1 to 64
(However, DI SIZE + DO SIZE ≤ 244 must be satisfied.)
Data length: 7
Data: C0 XX 3F 40 3F 40 YY
<8> Input size = 193 to 244, and output size = 1 to 64
(However, DI SIZE + DO SIZE ≤ 244 must be satisfied.)
Data length: 9
Data: C0 XX 3F 40 3F 40 3F 40 YY
<9> Input size = 65 to 128, and output size = 129 to 192
(However, DI SIZE + DO SIZE ≤ 244 must be satisfied.)
Data length: 8
Data: C0 3F 3F C0 3F YY 80 XX
<10>Input size = 129 to 192, and output size = 65 to 128
(However, DI SIZE + DO SIZE ≤ 244 must be satisfied.)
Data length: 8
Data: C0 3F 3F C0 XX 3F 40 YY
(b) Formats for using output only
<1> Input size = 0, and output size = 1 to 64
Data length: 2
Data: 80 XX
<2> Input size = 0, and output size = 65 to 128
Data length: 4
Data: 80 3F 80 XX
<3> Input size = 0, and output size = 129 to 192
Data length: 6
Data: 80 3F 80 3F 80 XX
<4> Input size = 0, and output size = 193 to 244
Data length: 8
Data: 80 3F 80 3F 80 3F 80 3F 80 XX