2.SETTING THE DATA SERVER FUNCTIONS SETTING B-64014EN/03
- 42 -
2.2 RELATED NC PARAMETERS
The NC parameters related to the Data Server functions are described
below.
#7 #6 #5 #4 #3 #2 #1 #0
0000 TVC
[Data type] Bit
TVC When a file is transferred from the personal computer to the Data
Server, a TV check is:
0: Not performed.
1: Performed.
NOTE
This parameter is valid only for text files.
For text files, see Subsection 2.1.3, "Text Files and
Binary Files" in Part II, "SPECIFICATION."
0020 I/O CHANNEL : Input/output device selection
[Data type] Byte
[Valid data range] 5 : Selects the Data Server as the input/output device.
#7 #6 #5 #4 #3 #2 #1 #0
0100 NCR CRF CTV
[Data type] Bit
CTV When a file is transferred from the personal computer to the Data
Server, character counting for the TV check in program comment
parts is:
0: Performed.
1: Not performed.
CRF When a file is output from the Data Server to the personal computer,
EOB (end of block) is:
0: Set as specified by parameter NCR (bit 3 of parameter No. 100).
1: Set to "CR" "LF".
NCR When a file is output from the Data Server to the personal computer,
EOB (end of block) is:
0: Set to "LF" "CR" "CR".
1: Set to "LF".
NOTE
This parameter is valid only for text files.
For text files, see Subsection 2.1.3, "Text Files and
Binary Files" in Part II, "SPECIFICATION."