5.SETTING THE MACHINE REMOTE DIAGNOSIS FUNCTIONS SETTING B-64014EN/03
- 74 -
No. #7 #6 #5 #4 #3 #2 #1 #0
F0082
RMTCLS
RMTCLS <F0082#3>
[Name] Completion signal for machine remote diagnosis cancel acceptance
[Classification] Output signal
[Function] Notifies that a request to cancel machine remote diagnosis has been
accepted.
[Output condition] When machine remote diagnosis is canceled after the signal to request
machine remote diagnosis cancellation (DIASTP) is set to "1", this
signal is set to "1". When the signal to request machine remote
diagnosis cancellation (DIASTP) is set to "0", this signal is set to "0".
No. #7 #6 #5 #4 #3 #2 #1 #0
F0083
RMTCAN RMTEND
DIAST5 DIAST4 DIAST3 DIAST2 DIAST1 DIAST0
RMTCAN <F0083#7>
[Name] Reject signal for machine remote diagnosis acceptance
[Classification] Output signal
[Function] Notifies that a machine remote diagnosis request has been rejected.
[Output condition] When the signal to request machine remote diagnosis (DIAREQ) is set
to "1", a request to start machine remote diagnosis is issued to the
machine remote diagnosis accepting server. When the server rejects
the request, this signal is set to "1". When the signal to request
machine remote diagnosis (DIAREQ) is set to "0", this signal is set to
"0".
RMTEND <F0083#6>
[Name] Completion signal for machine remote diagnosis acceptance
[Classification] Output signal
[Function] Notifies that a machine remote diagnosis request has been accepted by
the machine remote diagnosis accepting server.
[Output condition] When the signal to request machine remote diagnosis (DIAREQ) is set
to "1", a request to start machine remote diagnosis is issued to the
machine remote diagnosis accepting server. When the server accepts
the request, this signal is set to "1". When the signal to request
machine remote diagnosis (DIAREQ) is set to "0", this signal is set to
"0".