B-65302EN/01 SPECIFICATIONS FOR THE βiS SERIES 4.CONDITIONS FOR APPROVAL RELATED TO THE IEC60034 STANDARD
- 85 -
4.2.6 Heat Protection (IEC60034-11)
The heat protection type is as listed below:
T P 2 1 1
1 : Temperature rise limit category 1 for heat protection
1 : Stop only at stage 1 (no warning)
2 : Protection for gradual and abrupt overload
4.2.7 Grounding (IEC60204-1)
For each servo motor, continuity between the ground terminal and
housing of the power connector has been checked based on the
IEC60204-1 safety standard and it has been ensured that it satisfies
the standard.
4.2.8 Remarks
For details on EMC compliance authorization, refer to the separate
manual "Compliance with EMC Directives"