B-65302EN/01 SPECIFICATIONS FOR THE βiS SERIES 2.HOW TO USE SERVO MOTORS
- 7 -
2.1 USE ENVIRONMENT FOR SERVO MOTORS
2.1.1 Ambient Environment
Ambient temperature
The ambient temperature should be 0°C to 40°C. To operate this
series in an ambient temperature higher than the above, the use
conditions must be relaxed so that the motor or Pulsecoder does not
overheat. (The values in the data sheet are determined for an ambient
temperature of 20°C.)
Ambient humidity
The ambient humidity should be 80%RH or less and no condensation
should not be caused.
Vibration
When installed in a machine, the vibration applied to the motor must
not exceed 5G.
Installation height
Up to 1,000 meters above the sea level requires, no particular
provision for attitude. When operating the machine at a higher level,
special care is unnecessary if the ambient temperature is lowered 1°C
at every 100m higher than 1,000m. For example, when the machine is
installed at a place of 1,500 meters above sea level, there is no
problem if the ambient temperature is 35°C or less. For higher
temperatures, it is necessary to limit the output power.
If any one of the four environmental conditions specified above is not
satisfied, the output must be restricted.