B-65302EN/01 SPECIFICATIONS FOR THE βiS SERIES 2.HOW TO USE SERVO MOTORS
- 17 -
2.2.3.2 Connectors on the cable side (for signal : models β
ββ
β0.2is and
β
ββ
β0.3is)
The signal connector on the cable side for β0.2iS and β0.3iS is not
dripproof. To connect the cable, a dedicated crimping tool must be
used. Consider crimping, cable clamp, and voltage drop. Also note
that there are restrictions.
For signal
Housing specification
(Tyco Electronics AMP)
1-1318118-6 (D-2100D 12-position receptacle housing)
Contact specifications
(Tyco Electronics AMP)
1318107-1
(D-2 receptacle contact M)
1318108-1
(D-2 receptacle contact S)
Applicable wire size 0.18 to 0.5 mm
2
0.3 to 0.85 mm
2
0.08 to 0.2 mm
2
Insulation external diameter φ0.88 to 1.5 mm φ1.1 to 1.87 mm φ0.88 to 1.5 mm
Applicable crimping tool
1463475-1
(Dedicated crimping tool)
1276654-1
(D-2 M standard tool)
1276653-1
(D-2 S standard tool)
The following signal connector kit is available:
For signal
Connector kit specification (FANUC specification) A06B-6114-K241
Contents of the connector kit
Receptacle housing (1-1318118-6)×1
Receptacle contact D-2 M (1318107-1)×12
The following dedicated tools are required for this connector.
Applicable contact
Tyco Electronics AMP
specification
FANUC specification
D-2 contact size M
(Dedicated crimping tool for which the
applicable wire size is 0.18 to 0.5 mm
2
.)
1463475-1 A06B-6114-K242
D-2 contact size M 1276654-1 A06B-6110-K220#D2M
Crimping tool
D-2 contact size S 1276653-1 -
Extractor D-2 contact 1276716-1 A06B-6110-K220#D2R
NOTE
1 When you use the recommended wire (cable
diameter of 0.18 to 0.5 mm
2
) only with one D-2 size
M contact, the above dedicated crimping tool is
required.
Use a standard crimping tool for a D-2 contact
within the applicable range, with checking the size
of the wire to be used, contact type, and crimping
tool specification.
2 The contacts are of the type which crimps the
covering in addition to the wire. Follow the
dimension of the insulation part listed above. An
insulation of a diameter outside the above range
may be able to be connected depending on the
wire or tool, however. For details, contact the
connector manufacturer.