Edit
Title
10/16
Date Design Description
FANUC AC SERVO MOTOR βiS series
for package D DESCRIPTIONS
B-65302EN/01-004
05.08.22 H. Uematsu
Draw. No.
01
AC Servo motor
βis for package D
6. The compare to standard model
Servo motor βiS series (for FS 0i ) has same specification as “common specification
( ambient temperature, allowable axis load, shaft runout precition ) ” , “outline drawing”,
“connection of power line”, “built-in brake” and so on. Please refer to “FANUC AC SERVO
MOTOR β
iS series DESCRIPTION B-65302JA”.
Servo motor βiS series (for FS 0i)
The same
specification motor
βiS 2/4000 (for FS 0i) βiS 2/4000
βiS 4/4000 (for FS 0i) βiS 4/4000
βiS 8/3000 (for FS 0i) βiS 8/3000
βiS 12/2000 (for FS 0i) βiS 12/2000
β
iS 12/3000
βiS 22/1500 (for FS 0i) βiS 22/2000
The other side, it is different from standard model as “how to use servo motor”,
“conditionsfor approval related to the IEC60034 standard”, “over load duty”. Please pay
attention to these.
7. How to use servo motor
Basically, it is same as servo motor βiS series of standard. Please refer to FANUC AC
SERVO MOTORβ
iS series DESCRIPTION B-65302JA - Section 2. How to use servo motor.
The following is a different point from standard.
- It is important of setting the parameter for solt sermal alarm. Please set the parameter as this
DESCRIPTION.
- It must not attach a rear fan unit to this motor because of a possibility of missing the over
heat protection.
- Don’t it use on the condition of the strong wind flow to pulsecoder.
- When the soft thermal alarm has occured, please re-start CNC after several minutes.
WARNING