(3)Manual handle feed multiplication is not correct
Check the following signals using PMC’s PCDGN. Also confirm the
following parameters based on the parameter list.
#6 #5
MP2
#4
MP1
#3 #2 #1 #0
In handle mode, the travel distance per step can be changed.
MP2 MP1 Step feed Handle feed
0
0
1
1
0
1
0
1
1
10
100
1000
1
10
Mn
Nn
#7
7102
#6 #5 #4 #3 #2 #1 #0
HNGx
PARAM
#0(HNGx) The direction of rotation of the manual pulse generator and the direction
of the travel of the machine are:
0 : Same
1 : Opposite
7110 Number of manual pulse generators used (1 to 3).
PARAM
(4)The specified axis is the index table indexing axis. <M series>
For the index table indexing axis (B–axis), jog feed, incremental feed,
and manual handle feed cannot be performed.
#7
QG0153+
GFKE-0222-EN
11.TROUBLESHOOTING
739