[Backup unit Enable] When this check box is checked, the registry and
files are automatically saved during power–down. After power–down,
the special battery is used to supply the power during saving.
[High Priority] This check box is used to set the priority of automatic backup
task. To save some files with an application, uncheck this check box.
[Alarm for backup] This check box is used to set the interval in days at
which a message appears to prompt the user for manual saving when the
system operates for an extended period of time.
On the option setting screen, application programs can be registered.
When a program uses the data window library, the program does not run
unless it is started after the work area for the data window library is
initialized. By registering such a program in Ncboot32.exe, it can be
executed after the initialization of the work area for the data window
library.
Application programs are registered for each node.
[Node] selects a node. In the list box in the center of the screen, the
programs registered for the selected node are displayed.
[New...] registers a new program. When a blank character is included in
the path, it is enclosed with double quotation marks.
[Remove] deletes a selected line.
[Edit] allows editing of a selected line. This button is used to edit
arguments. The character string %d in the command line is replaced by
a node number. To represent % itself, describe %%.
Example: To start basic operation package 1 after initialization of the
work area for the data window library of the node, describe the
following:
”C:\Program Files\Basic Operation Package 1\WinBOP32.exe”
/Node=%d
NOTE
For the 160is/180is/210is, the option setting screen is not
provided.
F.4.3
Option Setting Screen
(160i/180i/210i Only)
F. MAINTENANCE OF OPEN CNC
(BOOT–UP AND IPL)
GFKE-0222-EN
APPENDIX
964