2002/08/09 T.Inagaki E.Genma
(8) Measurement of two point (parameter No.1802#2(DC2)=1)
(a) Please set the direction of the scale zero point in the parameter (No.1817#4 (SCP))
correctly at two point measurement. Because an incorrect coordinate system will be
established when a wrong value is set in parameter SCP. It is very dangerous. In this
case, please execute reference point return again after setting the correct value in
parameter SCP.
(b) Because an incorrect value is set in parameter No.1883 and 1884 when setting
parameter SCP is incorrect when the automatic setting of parameter No.1883 and
1884 was executed. It is very dangerous. In this case, please execute automatic
setting of parameter No.1883 and 1884 again after setting the correct value in
parameter SCP.
(9) Straightness compensation function
When the reference point establishment of moving axis is executed after the
establishment of compensation axis, the compensation axis is moved by straightness
compensation amount when the reference point of moving axis is established.
A-78754EN
FANUC Series 16i/18i/21i –B, 0i –B/C
Linear scale I/F with absolute address referenced
mark / Distance coded scale
Drawing No.
Page
Descri
tionDate Edit
10/32
03 2004/11/30 T,Inagaki (3) is added or altered.
02 2002/11/18 T
Ina
aki
2
is added or altered. E.Genma
Title