2002/08/09 T.Inagaki E.Genma
4. Parameter
#7 #6 #5 #4 #3 #2 #1 #0
1815 DCRx DCLx OPTx
[Data type] Bit axis
OPTx Position detector
0: A separate pulse coder is not used.
1: A separate pulse coder is used.
DCLx As a separate position detector, the linear scale with reference absolute
addressing mark (A/B phase) / the Linear scale with distance-coded
reference marks (serial) is:
0: Not used.
1: Used
Caution
When using the linear scale with reference absolute addressing marks
(A/B phase) or the linear scale with distance-coded reference marks
(serial, full closed system), also set the OPTx parameter (bit 1 of
parameters No.1815) to '1'. But when using the linear scale with
distance-coded reference marks (serial, linear motor system), please
set the OPTx parameter (bit 1 of parameters No.1815) to '0'.
DCRx As a scale with absolute addressing referenced marks:
0: The linear scale is used.
1: The rotary encoder is used.
Caution
1. Please set parameter DCLx to '1', too.
2. When the rotary encoder with distance-coded reference marks (serial
output circuit C) is used, please set this parameter to ‘0’.
(3)
#7 #6 #5 #4 #3 #2 #1 #0
1817 SCRx
[Data type] Bit axis
SCRx Specifies whether to convert scale data so that rotary axis B type is
available for the axis using a rotary scale without rotary data
0: not to convert
1: to convert
Title
Note
1. It is necessary to turn the CNC off after setting this parameter.
2. This parameter is available for only the rotary axis B type.
3. Don't set this parameter in the case of no discontinuous point within
movable range of rotary axis even if rotary axis B type.
4. Perform reference position establishment again when this parameter
was changed.
(3)
A-78754EN
FANUC Series 16i/18i/21i –B, 0i –B/C
Linear scale I/F with absolute address referenced
mark / Distance coded scale
Drawing No.
Page
Descri
tionDate Edit
18/32
03 2004/11/30 T,Inagaki (3) is added or altered.
02 2002/11/18 T
Ina
aki
2
is added or altered. E.Genma