2002/08/09 T.Inagaki E.Genma
(3)
1867 threshold value converting scale data (all axes)
[Data type] 2-word
[Unit of data]
Increment system IS-A IS-B IS-C Unit
Rotation axis 0.01 0.001 0.0001 deg
[Data range] 0 to 99999999
In the case that scale data is larger than this parameter value, it is converted to
be continuous data in movable range by subtracting one rotary data. The scale
data out of movable range (angle from a discontinuous point) must be set as
threshold value. This parameter is for all axes. In the case that the parameter
for each axis (Prm. No. 1868) is not 0, this parameter is not available.
1868 threshold value converting scale data (each axis)
[Data type] 2-word axis
[Unit of data]
Increment system IS-A IS-B IS-C Unit
Rotation axis 0.01 0.001 0.0001 deg
[Data range] 0 to 99999999
In the case that scale data is larger than this parameter value, it is converted to
be continuous data in movable range by subtracting one rotary data. The scale
data out of movable range (angle from a discontinuous point) must be set as
threshold value. As for the axis with this parameter = 0, the parameter
(No.1861) for all axes is available.
Note
1. When parameter Nos.1867/1868 are set, the power must be turned off
before operation is continued.
2. When parameter Nos.1867/1868 are converted, reference position
return must be performed again.
3. The parameter Nos.1867/1868 are available for only axis with
No.1817#3=1.
A-78754EN
FANUC Series 16i/18i/21i –B, 0i –B/C
Linear scale I/F with absolute address referenced
mark / Distance coded scale
Drawing No.
Page
Descri
tionDate Edit
22/32
03 2004/11/30 T,Inagaki (3) is added or altered.
02 2002/11/18 T
Ina
aki
2
is added or altered. E.Genma
Title