2002/08/09 T.Inagaki E.Genma
1883 Distance from the zero point of the linear scale with absolute addressing
reference marks (A/B phase) to the reference position /
Distance from the standard point of the linear scale I/F with absolute address
referenced mark (serial) to the reference position
(3)
[Data type] 2-word axis
[Unit of data] Detection unit
[Data range] -99999999 to 99999999
1884 Distance-2 from the zero point of the linear scale with absolute addressing
reference marks (A/B phase) to the reference position /
Distance-2 from the standard point of the linear scale I/F with absolute
address referenced mark (serial) to the reference position
(3)
[Data type] word axis
[Unit of data] Detection unit
[Data range] -20 to 20
When the distance between scale zero and reference position is over the
setting range of parameter 1883, please set this parameter.
Caution
On using the linear scale with distance-coded reference marks (serial),
when the value of this parameter is out of range, P/S alarm 5325 may
occur on trying to establish the reference point.
(3)
Set the distance between scale zero and reference position by parameter
No.1883, 1884 in case of the linear scale with absolute addressing reference
marks (A/B phase). Set the distance between standard point and reference
position by parameter No.1883, 1884 in case of the linear scale I/F with
absolute address referenced mark (serial). The actual distance is determined
by following formula:
Actual distance = Parameter 1884 * 100,000,000 + Parameter 1883
A-78754EN
FANUC Series 16i/18i/21i –B, 0i –B/C
Linear scale I/F with absolute address referenced
mark / Distance coded scale
Drawing No.
Page
Descri
tionDate Edit
25/32
03 2004/11/30 T,Inagaki (3) is added or altered.
02 2002/11/18 T
Ina
aki
2
is added or altered. E.Genma