2002/08/09 T.Inagaki E.Genma
#7 #6 #5 #4 #3 #2 #1 #0
1802 DC2 DC4
[Data type] Bit
DC4 When the reference position is established on the linear scale with
reference marks:
0: An absolute position is established by detecting three reference marks.
1: An absolute position is established by detecting four reference marks.
Caution
This parameter is unavailable on the linear scale with distance-coded
reference marks (serial).
DC2 The reference position on the linear scale with absolute addressing
referenced mark is established:
0: As determined by bit 1(DC4) of parameter No.1802.
1: By establishing the absolute position through detection of two reference
marks.
Caution
1. When this parameter is set to 1, set the direction of scale zero in the
parameter (No.1817#4(SCPx)) correctly.
2. Even if DC2 is "1", the rotary axis(parameter1815#3(DCRx)=1) follows
DC4.
3. This parameter is unavailable on the Linear scale with distance-coded
reference marks (serial).
A-78754EN
FANUC Series 16i/18i/21i –B, 0i –B/C
Linear scale I/F with absolute address referenced
mark / Distance coded scale
Drawing No.
Page
Descri
tionDate Edit
19/32
03 2004/11/30 T,Inagaki (3) is added or altered.
02 2002/11/18 T
Ina
aki
2
is added or altered. E.Genma
Title