2002/08/09 T.Inagaki E.Genma
[The setting method of parameter No.1883]
(Linear scale with distance-coded reference marks (serial))
You can determine the setting value by the following procedure.
(1)Set "1" to parameter No.1815#2 to make this function available.
Set "0" to parameter No.1240.
Set "0" to parameter No.1883,1884.
(2)Establish a reference point by the procedure described in "1.3.1 Procedure
for Reference Position Establishment". (As a result, the machine coordinate
becomes the distance between standard point zero and actual position.)
(3)
(3)Positioning the axis to reference position by mechanical measurement in
"HND" or "JOG" mode.
(4)Set an actual machine coordinate value (DGN.301) to the parameter
No.1883 after conversion of least command increment to detection unit.
(Multiply DGN.301 and CMR)
(5)Set a parameter No.1240 if necessary.
Note
When the setting value is greater than 99,999,999, this method can not
be used.
Do not set the scale zero inside the scale movable area. Please set the
scale zero out of the scale movable area.
(3)
A-78754EN
FANUC Series 16i/18i/21i –B, 0i –B/C
Linear scale I/F with absolute address referenced
mark / Distance coded scale
Drawing No.
Page
Descri
tionDate Edit
29/32
03 2004/11/30 T,Inagaki (3) is added or altered.
02 2002/11/18 T
Ina
aki
2
is added or altered. E.Genma
Title