2002/08/09 T.Inagaki E.Genma
3.3 Reference Position Return
(1) When the reference position is not established and the axis moved by turning the
feed axis direction signal (+J1,-J1,+J2,-J2,...) to “1” in REF mode, the reference
position establishment procedure is executed.
(2) When the reference position is already established and the axis is moved by turning
the feed axis direction signal (+J1,-J1,+J2,-J2,...) to “1” in REF mode, the axis is
moved to the reference point without executing the reference position establishment
procedure.
(3) When the reference position is not established and the reference position return
command (G28) is executed, the reference position establishment procedure is
executed. The next movement the axis depends on the setting of PRM
No.1818#0(RFS).
(4) When the reference position is already established and the reference position
command (G28) is executed, the movement of the axis depends on the setting of PRM
No.1818#1(RF2).
A-78754EN
FANUC Series 16i/18i/21i –B, 0i –B/C
Linear scale I/F with absolute address referenced
mark / Distance coded scale
Drawing No.
Page
Descri
tionDate Edit
13/32
03 2004/11/30 T,Inagaki (3) is added or altered.
02 2002/11/18 T
Ina
aki
2
is added or altered. E.Genma
Title