2002/08/09 T.Inagaki E.Genma
3. Specifications (Linear scale with distance-coded reference
marks (serial))
3.1 Procedure for Reference Position Establishment
(1) Select the JOG mode, and set the manual reference position return selection signal
ZRN to "1".
(2) Set a direction selection signal(+J1,-J1,+J2,-J2,…) for a target axis.
(3) The axis is fed at a constant low speed (reference position return FL feedrate specified
by parameter (No.1425) setting).
(4) When the absolute position of linear scale with distance-coded reference marks (serial)
is detected, the axis stops. Then the absolute position of CNC is calculated and
reference position establishment signal (ZRF1,ZRF2,ZRF3,+ _…) turns to "1".
The axis does not stop and reference position establishment is proceeded even if the feed
axis direction selection signal (+J1,-J1,+J2,-J2,…) turns to "0" between step (2) and (4).
The timing chart for this procedures is given below.
JOG
ZRN
+J1
Reference mark
ZRF1
Feedrate
FL rate
Fig.3 Timing chart for reference position establishment
A-78754EN
FANUC Series 16i/18i/21i –B, 0i –B/C
Linear scale I/F with absolute address referenced
mark / Distance coded scale
Drawing No.
Page
Descri
tionDate Edit
11/32
03 2004/11/30 T,Inagaki (3) is added or altered.
02 2002/11/18 T
Ina
aki
2
is added or altered. E.Genma
Title