2002/08/09 T.Inagaki E.Genma
(3)
[ In case of linear scale with absolute addressing reference mark (A/B phase)]
The scale zero means a point where reference mark 1 and reference mark 2 are
equal. Generally, this is a virtual point that exists on the out of scale
stroke.( Refer to following figure )
When a reference point is located in plus side of a scale zero, set a plus value
to this parameter. And a reference point is located in minus side, set a minus
value.
Mark1 Mark2
Mark1 Mark2
Scale zero
Scale end
…….
Mark1=Mark2
41.8
8.2 42.0
8.0
PRM.1821
PRM.1882
PRM.1884 × 100,000,000 + PRM.1883
Reference point
(3)
[ In case of the linear scale I/F with absolute address referenced mark (serial)]
In case of the linear scale I/F with absolute address referenced mark (serial),
the distance between standard point and reference position is set by parameter
No.1883, 1884. Standard point means the scale end as the following figure.
Reference position
Standard point
Mark1Mark2 Mark1
Mark2Mark1Mark1 Mark2
10.020 9.980 10.040 9.960
10.060 9.940
20.000
20.020
PRM.1884 × 100
000
000 + PRM.1883
A-78754EN
FANUC Series 16i/18i/21i –B, 0i –B/C
Linear scale I/F with absolute address referenced
mark / Distance coded scale
Drawing No.
Page
Descri
tionDate Edit
26/32
03 2004/11/30 T,Inagaki (3) is added or altered.
02 2002/11/18 T
Ina
aki
2
is added or altered. E.Genma