#7 #6 #5 #4 #3 #2 #1 #0
1818 SDCx RF2x RFSx
[Data type] Bit axis
RFSx If an automatic reference position return (G28) is made before the
reference position is established, the reference position is established first
then,
0: A movement to reference position is made.
1: A movement to reference position is not made.
RF2x If an automatic reference position return (G28) is made after the reference
position is established,
0: A movement to the reference position is made.
1: A movement to the reference position is not made, but the operation is
completed.
SDCx Linear scale with distance-coded reference marks (serial) is
0: Unavailable.
1: Available.
Warning
If you set parameter 1818#3(SDCx), please don't forget to turned off
before operation is continued. This parameter doesn't generate P/S
alarm 0 (Power-off alarm).
#7 #6 #5 #4 #3 #2 #1 #0
1819 DAT
[Data type] Bit axis
DATx When manual reference point return is executed, the automatic setting of
paramete 1883,1884 is:
0: Not executed.
1: Executed.
The procedure of the automatic setting are following :
(1) Set a correct value to parameter No.1815,1821,1882.
* On the linear scale with distance-coded reference marks (serial),
parameter No.1882 is unnecessary to set.
(2) Positioning the axis to reference position by mechanical measurement by
manual operation.
(3) Execute manual reference point return.
When the manual reference point return is finished, parameter
No.1883,1884 are set and No.1819#2 is turn to '0'.
A-78754EN
FANUC Series 16i/18i/21i –B, 0i –B/C
Linear scale I/F with absolute address referenced
mark / Distance coded scale
Drawing No.
Page
Descri
tionDate Edit
20/32
03 2004/11/30 T,Inagaki (3) is added or altered.