B-63434EN/02 CONNECTION 2.CONNECTION OF THE COMMUNICATION FUNCTION
- 115 -
An example of cross cable connection between the FL-net board
10BASE-T interface CD38N and a mediate converter (or hub) is
given below.
FL-net board
CD38N
TX+ (1)
TX- (2)
RX+ (3)
RX- (6)
(3) TX+
(6) TX-
(1) RX+
(2) RX-
MAX.100m
RJ-45
modular connector
Media converter
or hub
Shield
1TX+
2TX-
3RX+
4
5
6RX-
7
8
1TX+
2TX-
3RX+
4
5
6RX-
7
8
- The cable must not be longer than 100 m. Do not extend the
cable unnecessarily.
NOTE
A straight cable is usually used for connection
between a communication device and hub. The
cable required for connection may differ depending
on the manufacturer of the hub or media converter,
however. Check whether a straight or cross cable
is required, then prepare a correct cable.
When connection is correct, the LED marked with
"LIL" on the FL-net board lights up.