For each FL-net function used, the parameters below need to be set.
A. Cyclic transmission of common memory area 1
Basic parameters
Area 1 allocation parameters
B. Cyclic transmission of common memory area 2
Basic parameters
Area 2 allocation parameters
C. Message transmission
Basic parameters
Message allocation parameters
For B (Cyclic transmission of common memory area 2) and C
(message transmission) above, operation based on a user program
needs to be performed as required. For information about required
operation, see Chapter II DESCRIPTION Section 2.2 and Chapter 3,
respectively.
When the state monitoring parameters are set, the user program can
monitor the state of the local node and the network participation state
of other nodes. Perform node state monitoring as required.
CAUTION
Input/output data in common memory area 1 and
common memory area 2 is transferred
asynchronously with ladder program execution. So,
the concurrency of input/output data consisting of
multiple bytes may not be guaranteed. When word
data is input or output, for example depends on the
setting condition, the higher byte may be updated
some time after the lower byte is updated. For
details, see Chapter II DESCRIPTION Section 2.5.