TITLE
Modification of FANUC FL-net Board
OPERATOR’S MANUAL
Addition of the following item 3 to NOTE of Page 40
NOTE
3 When receiving the response message before receiving the ACK frame
as the acknowledgement of a request message, Request status(R_STS)
may not become 01h.
Replacement of “3.8. Byte List of Message Data” of Page 62
3.8 Byte List of Message Data
The interrelation among the byte lists in a virtual address space, the PMC area, and
FL-net network is described as follows。
Byte block data
On FL-net network Virtual address PMC area
7 0 7 0 7 0
+00 12H +00 12H +00 12H
+01 34H +01 34H +01 34H
+02 56H +02 56H +02 56H
+03 78H +03 78H +03 78H
By setting the bit 2 of the FL-net parameter OPTION1 to 1, a byte list is swapped as
follows.
On FL-net network Virtual address s PMC area
7 0 7 0 7 0
+00 12H +00 12H +00 34H
+01 34H +01 34H +01 12H
+02 56H +02 56H +02 78H
+03 78H +03 78H +03 56H
NOTE
The OPTION1 parameter is available when Communication setting
software (654I series) is edition 04 or later and when FL-net control
software (6564 series / 656C series ) is edition 07 / 01 or later
SHEET
6/17
DESCRIPTIONDESIGN DATE EDIT
01 Mutai First issue
B-63434EN/02-1
FANUC LTD.
02.05.20
DRAW.NO.