B-63434EN/02 OPERATION 1.PARAMETER SETTING
- 81 -
30036 Area 2 data exchange condition allocation address
[Data type] Word
[Valid data range] 0 - (only an even address)
[Index number] Pa43
30037 Switch flag allocation address
[Data type] Word
[Valid data range] 0 - (only an even address)
[Index number] Pa44
30050 Area 2 static DI data exchange address
[Data type] Word
[Valid data range] 0 - 8191
[Index number] Pa45
30051 Area 2 static DI data exchange size
[Data type] Word
[Valid data range] 0 - 8192
[Index number] Pa46
30055 PMC area allocation address (for DO)
[Data type] Word
[Valid data range] 68(D) or 82(R)
[Index number] Pa40
30056 PMC area allocation address (for DI)
[Data type] Word
[Valid data range] 68(D) or 82(R)
[Index number] Pa42
Message allocation parameters
30040 Interface allocation address
[Data type] Word
[Valid data range] 0 - (only an even address)
[Index number] Pa50
30041 Interface allocation size
[Data type] Word
[Index number] Pa51
30042 Receive message allocation address
[Data type] Word
[Valid data range] 0 - (only an even address)
[Index number] Pa52
30043 Receive message allocation data aize
[Data type] Word