TITLE
Modification of FANUC FL-net Board
OPERATOR’S MANUAL
Error messages which are displayed when data exchange fails
When the cyclic data can not be exchanged or the message data can not be transferred, the
following error messages are displayed.
In that case, please check the parameters written in each explanation.
ADDRESS(????, ????) OVERLAPPING
The local common area (area1 and area2) overlaps with the other node.
In that case, DO data of the local node is not sent.
Please check the Pa11, Pa12, Pa13, and Pa14 parameters.
OWN NODE STATUS IS OUT OF RANGE
Local node information address is invalid.
In that case, the information is not copied into the specified PMC address.
Please check the Pa20 parameter.
- An even address should be configured.
- The specified address should be within PMC R address.
ENTRY NODE STATUS IS OUT OF RANGE
Participating node information address is invalid.
In that case, the information is not copied into the specified PMC address.
Please check the Pa21 parameter.
- An even address should be configured.
- The specified address should be within PMC R address.
INVALID DYNAMIC CHANGE FLAG
Switch flag allocation address is invalid.
In that case, the dynamic switch of the area2 can not be performed.
Please check the Pa44 parameter.
INVALID PARAMETER (COMMON MEMORY AREA1)
The allocation address of common memory area1 is invalid.
In that case, the cyclic data of area1 is not copied into the specified PMC address.
Please check the Pa30 parameter.
- An even address should be configured to Pa30.
- The specified address should be within PMC R address.
- The sum of Pa31 and Pa32 should be within the range 0-512 of area1.
NODE NUMBER(???) IS INVALID
The node number of “Information on other nodes” of area2 is not within the range of
1-254.
In that case, the “Information on other nodes” is not copied into the prescribed PMC
address.
Please confirm that a ladder program writes a node number of 1-254 to PMC R address
specified by Pa43.
INVALID DI PARAMETER (COMMON MEMORY AREA2)
The Allocation address of area2 DI data is invalid.
In that case, the area2 data is not copied into the specified PMC address.
Please check the Pa43 parameter.
SHEET
15/17
DESCRIPTIONDESIGN DATE EDIT
01 Mutai First issue
B-63434EN/02-1
FANUC LTD.
02.05.20
DRAW.NO.