2.CONNECTION OF THE COMMUNICATION FUNCTION CONNECTION B-63434EN/02
- 116 -
2.4.2 Cable wire
As twisted pair cables for 10BASE-T, unshielded cables (UTP cables)
are available on the market. For improved protection against noise
in an FA environment, however, use a common shielded category-5
twisted pair cable (STP cable).
Recommended cables (For standard)
Manufacturer name Specification Remarks
The Furukawa Electric Co., Ltd. DTS5087C-4P Twisted wire
Nissei Electric Co., Ltd. F-4PFWMF Solid wire
Contact point
Manufacturer name Contact point
Sales Division, the
Furukawa Electric
Co., Ltd.
2-6-1 Marunouchi Chiyoda Ward, Tokyo, 100-8233
TEL: 03-3286-3126 FAX: 03-3286-3979
Remarks
Tamachi Office,
Nissei Electric Co.,
Ltd.
MU Building 3F, 1-9-1 Minaminaruse, Machida City,
Tokyo 194-0045
TEL: 0427-29-2531 FAX: 0427-29-3375
Contact point
for overseas
sales
IWATANI International Corporation
Tokyo Head Office
21-8 NISHI-SHINBASHI 3-CHOME, MINATO-KU,
TOKYO, 105-8458, JAPAN
TEL:03-5405-5810 FAX:03-5405-5666
Telex:2524256 IWATYO J
Remarks A processed cable with the both terminal connector
is provided.
NOTE
The recommended standard cables cannot be used
with movable parts.
Recommended cable (For movable parts)
Manufacturer name Specification Remarks
Oki Electric Cable Co.,
Ltd.
AWG26 4P TPMC-C5-F(SB) FANUC-specific
cable