TITLE
Modification of FANUC FL-net Board
OPERATOR’S MANUAL
Manuals related to FANUC Series 21i-TB/MB
Manual name Specification number
Descriptions B-63522EN
Connection Manual(Hardware) B-63523EN
Connection Manual(Functions) B-63523EN-1
Operator’s Manual(For Lathes) B-63604EN
Operator’s Manual(For Milling Centers) B-63614EN
Maintenance Manual B-63525EN
Parameter Manual B-63610EN
Addition of the following Item 5 to NOTE of Page 19.
NOTE
5 When changing the node number to a new one with using the method of
“2.2.2.1.Dynamic DI data allocation of common memory area 2”, the
status of its node is indicated at the place corresponding to its node
number.
But, if the new node is not participating in FL-net network, the DI data of
the old node remain because the DI data from the new node can not be
received.
When the new node participates in the network, the new DI data are
copied to the corresponding DI area.
Addition of Unavailable communication detection flag to FA link layer state of Page 23
FA link layer state:
7 6 5 4 3 2 1 0
+1
(Reserved)
Node participation flag (1: Participate)
Unavailable communication detection flag (1: Detection)
Upper layer operation signal error flag (1: Error)
Common memory data valid flag (1: Valid)
Common memory setting complete flag (1: Complete)
Duplicate address detection flag (1: Duplicate address
detected)
SHEET
3/17
DESCRIPTIONDESIGN DATE EDIT
01 Mutai First issue
B-63434EN/02-1
FANUC LTD.
02.05.20
DRAW.NO.