1.PARAMETER SETTING OPERATION B-63434EN/02
- 78 -
1.2.2 Power Mate i-MODEL D/H
Procedure
When the CRT/MDI or FANUC touch panel is used as the LCD, set
parameters in the same way as for the Series 16i/18i/21i-A.
When the DPL/MDI Operation Package is used as the LCD, set
values for parameters Nos. 30000 and after.
For how to set parameters using the DPL/MDI Operation Package,
refer to "Power Mate i Operator’s Manual."
Basic parameters
30000 IP address (1)
[Data type] Byte
[Valid data range] 1 - 254
[Index number] Pa10
Set bits 0 to 7 of the IP address of the local node.
30001 IP address (2)
[Data type] Byte
[Valid data range] 0 - 255
[Index number] Pa10
Set bits 8 to 15 of the IP address of the local node.
30002 IP address (3)
[Data type] Byte
[Valid data range] 0 - 255
[Index number] Pa10
Set bits 16 to 23 of the IP address of the local node.
30003 IP address (4)
[Data type] Byte
[Valid data range] 192 - 223
[Index number] Pa10
Set bits 24 to 31 of the IP address of the local node.