2. MACRO COMPILER
B–62073E–2/03
12
Note
The boot system registers any file having the acceptable
format. Once registration has started, it cannot be halted.
If no backup file exists on a memory card or another storage
medium, the previously saved data of the file cannot be
restored in any way. To avoid such inadvertent registration
of files, make sure that the correct file has been selected
before registering it. Also, back up files at appropriate
intervals.
11)When the file has been successfully registered, the message
”PROGRAM COMPLETED” appears. Press the input key. The
DATA LOADING DIRECTORY screen [see Fig. 2.3.1 (e)] is
then displayed again.
12)Select “END” and press the input key. The main menu [Fig. 2.3.1
(c)] is then displayed again.
13)Select “2. SYSTEM DATA CHECK” to retrieve the contents of
F–ROM. After confirming that the P–CODE file has been
registered, press the input key to return the main menu [Fig. 2.3.1
(c)].
14)Select “END” on the main menu and press the input key. The
blinking message “LOADING CNC DATA” appears. The CNC
starts up about ten seconds later.
15)Make sure that the registered P–CODE file operates normally.
16)Remove the memory card from the memory card interface. The
card can be removed even when the CNC power is on.
(2) Procedure for registering a P–CODE program in F–ROM to a
memory card
1) Insert the memory card in the memory card interface of the CNC
unit to activate the boot system. See steps 1 and 2 of 2.3.1 (1),
Procedure for registering a P–CODE program in a memory card
to F–ROM.
2) Select “3. SYSTEM DATA SAVE” using the cursor keys, then
press the input key. The contents of F–ROM are retrieved, and
the following information is displayed on the screen:
SYSTEM DATA SAVE
FILE DIRECTORY
1. OPTIONA1 ( 2)
2. HELP MSG ( 2)
3. DGTL SRV ( 1)
4. NC BASIC (10)
5. PCD 256A ( 2)
6. PMC–NA0B ( 1)
7. MCR–CMPA ( 2)
END
*** MESSAGE ***
SELECT FILE AND HIT INPUT KEY
Fig.2.3.1 (f) DATA SAVE DIRECTORY SCREEN