B–62073E–2/03
4.CONVERSATIONAL MACRO FUNCTION
69
This is the function to control the processing for arrangement type
variables or one group of variable rows.
1) Clearing arrangement type variables, variable rows (continuous
reading of specified data)
2) Transfer from arrangement type variables, variable rows to variable
row
In each processing, control code ”G315” is commanded after defining the
arrangement, variable row, or data to each of the following control
variables.
#8511 : Transmission origin Data
#8512 : Transmission origin
Two–dimensional arrangement number or variable row head
variable number
#8513 : Transmission origin
Three–dimensional arrangement number
#8514 : Transmission destination
Two–dimensional arrangement number or variable row head
variable number
#8515 : Transmission destination
Three–dimensional arrangement number
Control code
G315 P (processing code) K (processing data number) ;
The processing code specifies the contents of the processing by a 3–digit
number. Zero–suppress is possible with the upper rank ”0”
P001 : Stores #8511 data from variable
(P1) specified by #8514 to K con–tinuous variables.
P002 : Transfers K continuous variables
(P2) data from variable specified by #8512, from variable
specified by #8514 to K continuous variables. (Ascending
sequence transfer)
P003 : Transfers K continuous variables
(P3) data from variable specified by #8512, from variable
specified by #8514 to K continuous variables. (Descending
sequence transfer)
P101 : Stores #8511 data from arrangement variable #1 specified by
#8514, #8515 to K continuous arrangement vari–ables.
P102 : Transfers K continuous arrangement variables data from
arrrangement variable specified by #8512, #8513, from
arrangement variable #1 specified by #8514, #8515 to K
continuous arrangement vari–ables. (As–cending sequence
transfer)
4.5.11
Arrangement Type
Processing of
Conversational Macro
Exclusive Variable