B–62073E–2/03
2.MACRO COMPILER
17
Note
Be sure to turn off the power of the CNC unit before inserting
or removing the adapter. Inserting or removing the adapter
while the CNC power is on can not only damage the CNC
unit and the ROM cassette but can also destroy
battery–retained data, such as NC programs and
parameters.
3) Turn on the power of the CNC unit while holding down the cursor
( and ) keys. The boot system is activated, and the following
screen appears:
SYSTEM MONITOR
1. SYSTEM DATA LOADING
2. SYSTEM DATA CHECK
3. SYSTEM DATA SAVE
4. FILE DATA BACKUP
5. END
*** MESSAGE ***
SELECT MODE AND HIT INPUT KEY
4) Check the contents of F–ROM. If a P–CODE program is already
registered, delete it. For the deletion procedure, see 2.3.1 (1)
Procedure for registering a P–CODE program in a memory card
to F–ROM, steps 3 to 7.
5) Select ”SYSTEM DATA LOADING” using the cursor keys, then
press the input key. The following contents of the ROM cassette
are read and displayed on the screen:
SYSTEM DATA LOADING (CASSETTE)
P–CODE 256K (WITHOUT SUB–CPU)
*** MESSAGE ***
SELECT FILE AND HIT INPUT KEY
Title
ROM
type
Fig.2.3.2 (e) DATA LOADING DIRECTORY SCREEN (for ROM Cassette)