2. MACRO COMPILER
B–62073E–2/03
16
Note
Items 1) to 5) were required when compiling programs for
Series 15–A using System P or a personal computer. Items
6) and 7) have been required for Series 15–B additionally.
(2) Procedure for registering a P–CODE program in a ROM cassette to
F–ROM
1) Connect the ROM cassette into which the program has been
written using System P or a personal computer to the ROM
cassette adapter (A20B–2000–0760).
ROM cassette adapter
(A20B–2000–0760)
ROM
cassette
Fig.2.3.2 (c) Connection of the ROM Cassette to
the ROM Cassette Adapter
2) Turn off the power of the CNC unit, then insert the ROM cassette
adapter into the mini slot of the CNC unit. The mini slot is on
the PSU and is protected with a cover when not in use.
ROM cassette
PMC PSU
Series 15–B
ROM cassette adapter