4. CONVERSATIONAL MACRO FUNCTION
B–62073E–2/03
68
#506=54
#507=65
#508=66
#509=67
#510=68
#511=<blank>
:
#531=<blank>
#8501=8
(1) Until the INPUT key is pressed, the previous value remains for the
contents of macro variable from number specified in #8552. The
INPUT key is pressed and first the value is set.
(2) The value of 8503, 8504 is not guaranteed.
(3) When a macro variable number other than 0 has been set in #8552,
if the INPUT key is pressed this function is unconditionally
performed. In that case, input by #8550 (character variable) cannot
be performed.
(4) Function–screen control variable
Variable #8530 indicates the function currently displayed on the CNC
screen.
Writing the following data into variable #8530 changes the screen to
the corresponding function screen.
#8530 : 0:Position screen
1:Program screen
2:Offset screen
3:Program check screen
4:Setting screen
5:Service screen
6:Alarm screen
7:Graphic screen (only when the option is used)
8:Conversational macro screen
11:Operation history screen
Note
If a value other than those described above is written, it is
ignored.
#8509 is the variable command to call the registered character string
program. Refer to Character display (Address P of G243) for detail.
Caution
4.5.10
Character String
Registered Program
Control Variable #8509