B–62073E–2/03
4.CONVERSATIONAL MACRO FUNCTION
53
(1) Starting up conversational macro program
Conversational macros can be executed by pressing the TALK
MACRO soft key or when activated by an auxiliary or execution
macro.
The program to be started up is the program number of the value of
the conversational macro execution control variable 1 (#8500). The
value of the conversational macro execution control variable 1
(#8500) when turning on the power is set by parameter (No.8536).
However, when the parameter (No.8536) is ”0”, the conversational
macro body cannot be started up.
If a conversational macro program having a program number
specified with conversational macro execution control variable
#8500 has not been compiled, the conversational macro function
executes no program resulting in a PS11 ‘3 IMPROPER
NC–ADDRESS alarm.
(2) Stopping the conversational macro
The conversational macro cannot be stopped by such as reset, single
block, feed hold. However, the conversational macro can be stopped
by either setting the parameter (No.8536) to ”0” or by setting the
conversational macro execution control variable 1 (#8500) to 0.
Further, it is possible to end the display of the conversational macro
screen and return to the screen which was displayed before selecting
the conversational macro screen by pressing the software key on the
left edge.