B–62073E–2/03
2.MACRO COMPILER
29
0 : Does not suspend data sending or receiving.
1 : Cancels the wait state for data sending or receiving.
STDM On the conversational macro screen, status display (mode and
status display) is:
0 : Not masked.
1 : Masked.
PMC-NB If the system features PMC–NB, writing or reading of
two–byte or four–byte data by G310 is done in the:
0 : PMC–NA format.
Two–byte data :
The high–order byte is assigned A. The low–order byte is
assigned A + 1.
Four–byte data :
The bytes are read or written in a sequence such that the
high–order byte is assigned the lowest address A, while the
low–order byte is assigned the highest address A + 3.
1 : PMC–NB format.
Two–byte data :
The low–order byte is assigned A. The high–order byte is
assigned A + 1.
Four–byte data :
The bytes are read or written in a sequence such that the
low–order byte is assigned the lowest address A, while the
high–order address is assigned the highest address A + 3.
2 bytes 4 bytes
A
A+1
A
A+1
A+2
A+3
#7 #6 #5 #4 #3 #2 #1 #0Address
8508 EXT1 CUTL BCAL ONMK SCAL TCAL ACL2 ACL1
Parameter input
Data format: bit type
ACL1 Sub program call by designated code (O9004/#146)
0 : disabled
1 : enabled
ACL2 Sub program call by designated code (O9005/#147)
0 : disabled
1 : enabled
TCAL Sub program call by T code (O9000/#149)
0 : disabled
1 : enabled
SCAL Sub program call by S code (O9029/#147)
0 : disabled
1 : enabled
ONMK O,N number display in conversational macro screen