4. CONVERSATIONAL MACRO FUNCTION
B–62073E–2/03
88
Alarm basic flag
I.D No.
(#8997)
Bit name Information contents
Error
code
BGPS (01H) Background P/S alarm
FGPS (02H) Foreground P/S alarm
OHALM (04H) OH alarm
– (08H) Undetermined
– (10H) Undetermined
SWON (20H) SW alarm
OTALM (40H) OT alarm
– (80H) Undetermined
EXTALM (100H) External alarm
– (200H) Undetermined
SRALM (400H) SR alarm
– (800H) Undetermined
SVALM (1000H) SV alarm
IOALM (2000H) I/O alarm
PWALM (4000H) PW alarm
– (8000H) Undetermined
External alarm:
When this bit is 1 it means that data has been set to external alarm
number 1, 2, 3, or 4.
SR alarm:
When this bit is 1 it means that data has been set to external alarm
number 1, 2, 3, or 4.
SV alarm:
When this bit is 1 it means that data has been set to SV alarm flag, or
axis type SV alarm flag 1, 2, 3, or 4.
IO alarm:
When this bit is 1 it means that data has been set to IO alarm flag.
PW alarm:
When this bit is 1 it means that data has been set to PW alarm flag.
Background P/S alarm:
When this bit is 1 it means that data has been set to P/S alarm number
(background).
Foreground P/S alarm:
When this bit is 1 it means that data has been set to P/S alarm number
(foreground).
OH alarm:
When this bit is 1 it means that data has been set to OH alarm flag
or axis type OH alarm flag.
SW alarm:
When this bit is 1 it means that data has been set to SW alarm flag.
OT alarm:
When this bit is 1 it means that data has been set to OT alarm flag 1,
2, 3 or 4, or axis type OT alarm flag 1, 2 or 3.