4. CONVERSATIONAL MACRO FUNCTION
B–62073E–2/03
96
SV axis type alarm flag 4
I.D No.
(#8997)
Bit name Information contents
Error
code
– (01H) Undetermined
SVABS (02H) Absolute pulse coder failure or
device position for greatly moving
the device when turning on power
was not correctly requested.
SV 101
– (04H) Undetermined
– (08H) Undetermined
– (10H) Undetermined
– (20H) Undetermined
– (40H) Undetermined
– (80H) Undetermined
SV axis type alarm flag 5
I.D No.
(#8997)
Bit name Information contents
Error
code
SVCVO (01H) When servo control is on, speed
control ready signal is on although it
should be off.
SV 025
SVARG (02H) Servo axis arrangement parameter
is not correctly set.
SV 026
– (04H) Undetermined
– (08H) Undetermined
– (10H) Undetermined
– (20H) Undetermined
– (40H) Undetermined
– (80H) Undetermined
Alarm number
I.D No.
(#8997)
Information contents
30 Foreground P/S alarm number
31 Background P/S alarm number
32 SR alarm number
33 External alarm number
34 External alarm number
35 External alarm number
36 External alarm number
(1) Reading relative coordinates
Reading the relative coordinate value can be performed by
conversational macro.
Set the axis number to perform relative coordinate value reading to
#8998, and the relative coordinate value can be read by #8999.
4.5.19
Reading Relative
Coordinates by
Conversational Macro,
and Preset