4. CONVERSATIONAL MACRO FUNCTION
B–62073E–2/03
92
OT alarm flag 4
I.D No.
(#8997)
Bit name Information contents
Error
code
OTHW (01H) Numerical value inputted by exter-
nal data input data signal
EID32–EID47 has exceeded per-
missable range.
OT 127
OTLL (02H) Numerical value inputted by exter-
nal data input data signal
EID00–EID31 has exceeded allow-
able range.
OT 128
OTREV (04H) Position coder CPU or peripheral
circuit are abnormal.
OT 129
8
OTNOR (08H) Status that program number,
sequence number search requests
cannot be received. (Because not
in memory mode or not in reset sta-
tus)
OT 130
OTCVT (10H) A/D converter has failed. OT 150
– (20H) Undetermined
OTOTR (40H) There were input requests for pot
number, offset number in the midst
of registering tool data by G10.
OT 131
– (80H) Undetermined
I/O alarm flag
I.D No.
(#8997)
Bit name Information contents
Error
code
– (01H) Undetermined
– (02H) Undetermined
– (04H) Undetermined
– (08H) Undetermined
– (10H) Undetermined
9
100VR (20H) Attempted to perform writing or
reading of data at address outside
file memory area.
IO 032
10SUM (40H) NC memory 1 page unit checksome
is not correct.
IO 303
10CHR (80H) Ilegal code has been read from NC
memory.
IO 031
SV alarm flag
I.D No.
(#8997)
Bit name Information contents
Error
code
SVESP (01H) Emergency stop has been applied. SV 030
– (02H) Undetermined
– (04H) Undetermined
– (08H) Undetermined
– (10H) Undetermined
– (20H) Undetermined
– (40H) Undetermined
– (80H) Undetermined