B–62073E–2/03
2.MACRO COMPILER
31
Address
8513 Custom macro G–CODE for calling O9010
8514 Custom macro G–CODE for calling O9011
8522 Custom macro G–CODE for calling O9019
Parameter input
Data format : word type
Data range : 1 to 255 (except for 65 to 67)
Specifies G–CODE to perform macro call by G–CODE.
Address
8523 Custom macro M code to call O9020
8524 Custom macro M code to call O9021
8532 Custom macro M code to call O9029
Parameter input
Data format : word type
Data range : 0 to 9999
Specifies M–CODE to perform macro call by M code.
Address
8533 M code for calling a user program
Parameter input
Data type : Word
Valid data range : 0 to 99
Note) M00, M01, M02, M30, M98, and M99 cannot be used to call a user
program.
A P–CODE program (execution macro program) called by a user program
can call another user program as a subprogram, according to the specified
M code.
Address
8536
Value of conversational macro execution control variable 1 when turning on power
Parameter input
Data format : word type
Data range : 0 to 9999
Sets the program number of the first conversational macro to be executed
after power–on. This value is set in conversational macro execution
control variable 1 (#8500).
Address
8537
Value of conversational macro execution control variable 2 when turning on power
Parameter input
Data format : word type
Data range : 0 to 9999