B–62073E–2/03
4.CONVERSATIONAL MACRO FUNCTION
77
(14)End code (#8529)
Check the end code after running every processing.
#8526 Contents
0 Normal Completion
1 Double open has occurred
2 Cannot open because being used by another user
3 Cannot open because program does not exist
4 Attempted to edit program during operate
10 Specified program does not exist (has not been registered)
11 Specified program number already exists (cannot be newly created)
12 No vacant area in tape storage memory
13 No vacant area in directory (over the register number)
15 Attempted to edit language which cannot be edited
16 Attempted to edit program which cannot be edited
100 There is already background editing
101 Data protection key has been set OFF
102 Erroneous program number has been specified
103 Erroneous block number has been specified
104 Address not in address code table existed during editing(
There is not format ”address plus numerical value”)
105 There is an error in macro variable number for editing
253 The specified block is not of word type (address + numeric)
255 Parameter number 8508, EXT1 is 0
(15)Notes
Selection processing by work number search etc. is required in the
case foreground operation of a program which has been prepared and
edited processed with background functions.
(16)Address code table
Address Code Address Code Address Code
A 1 K 11 U 21
B 2 L 12 V 22
C 3 M 13 W 23
D 4 N 14 X 24
E 5 O 15 Y 25
F 6 P 16 Z 26
G 7 Q 17
H 8 R 18 EOB 27
I 9 S 19 EOR 28
J 10 T 20 / 29