2. MACRO COMPILER
B–62073E–2/03
28
1 : displayed
EUI0 For the P–CODE program (execution, conversational, and
auxiliary macros), the UI and UO signals range from
0 : UI00/UO00 to UI15/UO15
1 : EUI00/EUO00 to EUI15/EUO15
TMCC Macro calls by T codes are
0 : invalid
1 : valid
NPEF In RS–232–C control by conversational macros, the end of file
(EOF) mark (%) is
0 : output
1 : not output
#7 #6 #5 #4 #3 #2 #1 #0Address
8503 VR7 VR6 VR5 VR4 VR3 VR2 VR1 VR0
Parameter input
Data format: bit type
VR0 Macro variable for macro compiler (#100–149)
0 : uses the same as normal custom macro
1 : uses one for macro compiler
VR1 Macro variable for macro compiler (#150–199)
0 : uses the same as normal custom macro
1 : uses one for macro compiler
VR2 Macro variable for macro compiler (#500–549)
0 : uses the same as normal custom macro
1 : uses one for macro compiler
VR3 Macro variable for macro compiler (#550–599)
0 : uses the same as normal custom macro
1: uses one for macro compiler
VR4 Macro variable for macro compiler (#600–699)
0 : uses the same as normal custom macro
1 : uses one for macro compiler
VR5 Macro variable for macro compiler (#700–799)
0 : uses the same as normal custom macro
1 : uses one for macro compiler
VR6 Macro variable for macro compiler (#800–899)
0 : uses the same as normal custom macro
1 : uses one for macro compiler
VR7 Macro variable for macro compiler (#900–999)
0 : uses the same as normal custom macro
1 : uses one for macro compiler
#7 #6 #5 #4 #3 #2 #1 #0Address
8507 PMC–NB STDM ECAN
Parameter input
Data type: Bit type
ECAN While data receiving (G335) or data sending (G336) is in the
wait state under conversational macro RS–232–C control,
pressing the CANCEL key on the MDI/CRT panel: