13. FUNCTIONS TO SIMPLIFY
PROGRAMMING
B–64112EN/01
NC FUNCTION
116
Distrib-
uted
pulse
Spindle
motor
Gear ratio
n : m
Spindle
Gear ratio
1 : p
Spindle
amplifier
D/A
converter
Position
coder
Error
counter
Spindle control
(voltage calculation of
spindle speed rpm)
×4
DMR
×4
CMR
The Control System of Spindle during Rigid Tapping
Gear ratio of spindle to
position coder (1 : p)
Least command increment
(detection unit ) deg
1 : 1 0.088 (1x360 / 4096)
1 : 2 0.176 (2x360 / 4096)
1 : 4 0.352 (4x360 / 4096)
1 : 8 0.703 (8x360 / 4096)
Even use of the spindle motor incorporating the position coder enables
rigid tapping. In this case, the gear ratio of the spindle motor and the
spindle is set by the parameter.
In addition, use of the spindle motor incorporating the position coder
enables rigid tapping but disables threading and per revolution dwell.
Override with a previously set parameter value can be applied to the
pull–out operation.
Theoretically, it is possible to apply a pull–out override of up to 2000%
(20 times). (Also take machine–imposed restrictions into account.)
If an override result would exceed the maximum permissible spindle
rotation speed (specified in a parameter) for rigid tapping, the actual
spindle speed is clamped at the maximum permissible spindle rotation
speed.
Pull–out override
D Parameter setting–based
method