B–64112EN/01
5. FEED FUNCTIONS
NC FUNCTION
51
The per minute feed (G94) and per rotation feed (G95) can be overrided
by:
0 to 254% (per every 1%).
In inverse time, feed rate converted to per minute feed is overridden. Feed
rate override cannot be performed to F1-digit feed.
Feed rate also cannot be performed to functions as thread cutting and
tapping in which override is inhibited.
Rapid traverse rate can be overridden by:
F0, 25%, 50%, 100%.
F0: A constant speed per axis is set by parameter
An override of 0% to 100% can be applied in 1% steps using a signal.
Feed rate override and the second feed rate override can be clamped to
100% by a signal from the machine side.
The manual continuous feedrate and incremental feed rate can be
overridden by:
0% to 655.34% (in steps of 0.01%)
5.3
OVERRIDE
5.3.1
Feed Rate Override
5.3.2
Rapid Traverse
Override
5.3.3
Override Cancel
5.3.4
Jog Override