26. DISPLAYING AND SETTING DATA
B–64112EN/01
NC FUNCTION
250
On the spindle setting screen, parameters required for standard
initialization of the serial spindle are listed. The parameters can also be
set.
SPINDLE SETTING O0000 N00000
GEAR SELECT :1
SPINDLE :S11
(PARAMETER)
GEAR RATIO 50
MAX SPINDLE SPEED 3000
MAX MOTOR SPEED 6000
MAX C AXIS SPEED 100
>_
MDI **** *** *** 09:36:48
[ SP.SET ][ SP.TUN ][ SP.MON ][ ][ (OPRT) ]
On the spindle adjustment screen, parameters required for basic
adjustment of the serial spindle and statuses being monitored are listed.
SPINDLE TUNING O1000 N00000
OPERATION : SYNCHRONIZATION CONTROL
GEAR SELECT : 1
SPINDLE : S11
(PARAMETER) (MONITOR)
PROP.GAIN –2460 MOTOR 100
INT.GAIN 241 SPINDLE 150
LOOP GAIN 3000 POS ERR S1 100
MOTOR VOLT 30
ZRN GAIN % 100 SYN.ERROR 128
REF.SHIFT 2046
>_
MEM STAT MTN *** *** 09:36:48
[ SP.SET ][ SP.TUN ][ SP.MON ][ ][ (OPRT) ]
26.9.3
Spindle Setting Screen
26.9.4
Spindle Adjustment
Screen