B–64112EN/01
26. DISPLAYING AND SETTING DATA
NC FUNCTION
237
The load values (torque values) of spindle motor and servo motor are
displayed in bar chart.
The most recent sampling values are displayed in bar chart display. Set
the rated load value of motor corresponding to each load meter to
parameters. The load meter displays 100% when the load value is the
rated load value.
The load meter can be displayed up to three servo motor axes and a
parameter can be used to select any one of three axes.
A maximum of 25 of the most recent alarms generated in CNC can be
recorded. Each alarm record consists of the following items:
- Date and time
- Alarm number
- Alarm message
Any of the records can be deleted from the alarm history.
In addition, the operator message history can be displayed.
ALARM HISTORY O0100 N00001
02. 02. 14 16:43:48
010 IMPROPER G–CODE
02. 02. 13 8:22:21
506 OVER TRAVEL :+1
02. 02. 12 20:15:43
417 SERVO ALARM :X AXIS DGTL PARAM
MEM **** *** *** 09:36:48
[ ALARM ][ MSG ][ HISTORY ][ ][ (OPRT) ]
The history of external operator messages can be stored. The stored
history can be displayed on the external operator message history screen.
D Operating monitor
display
D Displaying the alarm
history
D Displaying external
operator message
history